Controlled-products-systems-group DL650 Bedienungsanleitung Seite 7

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 9
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 6
The Digi-Lock may accept four or five digit entry codes. 4-Digit codes are faster to enter
and program, but 5-Digit codes offer better security. The system is factory set to
4-Digit entry codes. To change the entry code length:
1. Press
2. Press (or new PAC)
Response BEEP! BEEP!
3. Press
4. Press or (Entry Code Length Desired)
5. Press
Response BEEP! BEEP!
6. Press Then
Page 4 Response BEEP! BEEP! BEEP! PROGRAM COMPLETE Page 9
PROGRAMMING INSTALLATION
Programming Relay 1 Activation Time Slave Keypad Wiring Connections (Option)
Relay 1 may be programmed to activate for 2 to 240 seconds. The factory
setting is 10 seconds. To program relay 1 activation time: A Slave keypad may be used with the system. All programming for the Slave keypad
is done through the normal programming of the Master Keypad. Nine (9) wires are
1. Press required between the Master and Slave keypad. To install the Slave keypad:
2. Press (or new PAC) 1. Install the Slave keypad within 500 feet of the Master keypad.
Response BEEP! BEEP! 2. Run a 22 AWG, 7-conductor shielded cable and a 22 AWG, 2-conductor
shielded cable from the Master to the Slave keypad.
3. Press 3. Connect the 7-conductor cable to the Slave keypad terminals in the same
order as the connection of the Master keypad. For example, connect Master
4. Press (Number of Seconds) pin 1 to Slave pin 1 etc.
4. Connect the 2-conductor cable from the Master 12V terminals directly to the
5. Press slave light wires. (Optional, if lighting is desired)
Response BEEP! BEEP! 5. Connect cable shields to the ground screw.
22 AWG 7-conductor
6. Press Then Shielded Cable
Response BEEP! BEEP! BEEP! PROGRAM COMPLETE
Programming Relay 2 Activation Time
To verify the PAC:
ground screw in the Digi-Lock.
Time Clock Feature
A time clock may be installed and used in conjunction with the Digital Lock. This will
allow certain entry codes to become valid only during designated times. The time
clock must provide a dry contact closure. To install a timer or clock:
1. Connect the clock relay output to TZONE and COM. (See diagram above)
2. Designate entry codes to be valid within the time zone. (See page 6, Step 6,
and Table 2.)
3. Time Zone designated entry codes will only be active while the dry contact is
is made across the TZONE and COM input.
4. Program the time clock to activate it's dry contact for the desired time(s).
Any timer or clock must provide a dry contact closure.
Failure to use a dry contact closure may cause the timer or
clock to burn out the circuit board and may cause a fire. If the
timer or clock plugs directly into an AC power source and it
has an AC output terminal, it does not prov ide a dry contact
closure and should not be used.
#