Install the Protector System
®
1 Install the Safety Reversing Sensors
OPTION C
FLOOR INSTALLATION
Use an extension bracket (notprovided) or wood block to raise the sensor bracket ifneeded.
1.1C Carefully measure the position of both
sensor bracketsso they will be the same
distance from the wall and unobstructed.
1.2C
Attach the sensor brackets to the floor
using concrete anchors (not
provided).
Insi
d
e
Garage
Wa
l
l
(not provided)
1.3C
Slide the carriage boltinto the sloton
each sensor.
Carriage Bolt
1/4" - 20 x 1/2"
1.4C
Insert the bolt through the hole in the sensor
bracketand attach with the wing nut. The lens
on both sensorsshould point toward each
other. Make sure the lensisnot obstructed by
the sensor bracket.
2 Wire the Safety Reversing
Sensors
OPTION A
INSTALLATION WITHOUT PRE-WIRING
PRE-WIRED INSTALLATIONS: If your garage
already has wires installed for the safety reversing
sensors, see page 20.
HARDWARE
Insulated Staple
(N
ot shown)
2.1A Run the wire from both sensors to the
garage door opener.Attach the wire to
the wall and ceiling with the staples.
2.2A Strip 7/16 inch (11 mm) of insulation
from each set of wires. Separate the
wires. Twist the white wires together.
Twist the white/black wires together.
2.3A Insert the white wires into the white terminal on
the garage door opener. Insert the white/black
wires into the grey terminal on the garage door
opener. To insert or remove the wires from the
terminal, push in the tab with a screwdriver tip.